Fabricated and installed return box, replaced thermostat and relocated supply grille in kitchen.

Hwy 178 South NINETY SIX, SC
2016-11-22


System is not heating. Found the heat exchanger cracked and bad control board. Customer looking to replace unit.

Eddy Road NINETY SIX, SC
2016-11-18


INstalled a 3 ton American Standard split gas/electric system

Mitchum Dr NINETY SIX, SC
2016-07-12


Duct work falling. Went and rewrapped duct, customer supplied.

Hwy 246 S NINETY SIX, SC
2016-07-08


Replaced evaporator coil and charged system. Unit is operating properly.

Maple Dr NINETY SIX, SC
2016-03-16


Program in t-stat is out of setting. Set heat all times to 69* anc cooling to 70*. If t-stat fails again, it will have to be replaced.

Sirrene St NINETY SIX, SC
2016-03-11


Found the t-stat bad and a condenser fan motor capacitor. System is operating properly.

Sirrene St NINETY SIX, SC
2016-03-07


No heat. Found a short in the low voltage wire. Replaced wire and checked system. Unit is operating at this time.

Hwy 246 S NINETY SIX, SC
2016-02-08


HVAC check. Had a leak on the suction line valve, replaced valve and stem, charged unit. Repaired duct work on unit. Unit is operating properly.

Maple Dr NINETY SIX, SC
2016-02-02


Replaced compressor in HVAC unit. Test operated and unit is operating properly.

Hwy 178 South NINETY SIX, SC
2016-02-01


Replaced thermostat and replaced some low voltage wire. Unit is operating properly.

Hwy 702 NINETY SIX, SC
2016-01-29


Water source system has a low charge and the coil is froze. Capacitor to the compressor is bad. Replaced a 35mfd capacitor and charged unit. Tested and unit is working properly.

Hwy 702 NINETY SIX, SC
2016-01-06


HVAC unit is not heating. Nitrogen leak searched and found a leak in the condenser coi. Unit needs to be replaced.

Summer Place NINETY SIX, SC
2016-01-06


HVAC unit is not working. Traced down and repaired voltage issue. Unit is working properly.

Sirrene St. NINETY SIX, SC
2015-12-29


Checked unit and found the defrost board bad. Replaced board and unit is working properly.

Martin Town Road NINETY SIX, SC
2015-12-21